INSTALLATION
INSTALLATION OF SIDE BURNER, BUILT-IN MODEL
All BGB131-BI and BGB132-BI models can be installed into a combustible enclosure with zero clearance from
the back, side and bottom below the counter top level as shown in Fig. 03.
A minimum of 6" from the back and sides must be maintained from the professional side burner above the
cooking surface (see Fig. 03).
When determining a suitable location, take into account concerns such as exposure to wind, proximity to
traffic paths, and keeping any gas supply lines as short as possible. Locate the side burner only inawell-
ventilated area. Never locate the side burner inagarage, breezeway, shed, or other such enclosed areas.
It is recommended that ventilation holes are provided in the enclosure in the event of a gas leak. The counter
and supporting ledges or deck must be level and flat.
Important!
Gas fittings, regulator, and installer-supplied shut-off valves must be easily accessible.
BACK Vl EW
!ioo!:i
___._COMBUSTIBLEOR
_NON=CONIBUSTIBLE :
_,_'//////////////////,
FIG.03