TROUBLE SHOOTING
PROBLEM POSSIBLE CAUSE CORRECTION
1. Ice consumption is low. Use the ice in the bin frequently. Ice will stick together if
left in insulated bin over long periods of time.
Ice cubes are sticking
together.
2. Room temperature is too Move the unit to an area where temperature is below 90
warm. degrees F.
Use a level to check the unit for level from side to side
1.The ice maker is not level, and front to rear.
2. Room temperature is too Move the unit to an area where temperature is below 90
warm. degrees F.
Ice level istoo high. 3. Ice deflector is not in place Check to see that the ice deflector is in place and secured
or secured properly, below the grid-cutter.
You can adjust the bin level sensing tube by simply
4. Bin level sensing tube pressing directly clown on the tube S inches from the
needs adjusting, front of the tube to get a desired bin level.
Use a level to check the unit for level from side to side
1.The ice maker is not level, and front to rear.
2. Room temperature is too Move the unit to an area where temperature is above 55
Ice level istoo low. cold. degrees F.
3.The selector switch is not in Set the rocker switch on the grill of the ice maker to the
the "ON" position. "ON" position.
Water keeps backing
up into the ice bin
(gravity drain).
Water keeps backing
up into the ice bin
(drain pump).
The drain pump
cycles on and off
erratically.
1. Inadequate drain system.
2. Foreign material in ice bin
drain.
1.Drain pump tubing kinked
or restricted.
2.Inlet screen to the drain
pump is restricted or blocked.
3. Drain pump and/or the ice
maker are not level.
1.Vent line to the drain pump
is restricted or kinked.
2. Discharge line is restricted
or kinked.
3.The drain pump is not level.
Restriction or improperly installed drain lines will cause
water to back up into the ice bin. Make certain there are
no kinks or restrictions in the drain lines. If necessary,
consult a qualified plumber.
Foreign material is restricting or blocking the ice bin
drain located at the right rear corner of the ice bin. The
drain will need to be cleared.
Check inlet, discharge, and vent line tubing for any kinks
or restrictions and repair as necessary.
Check the inlet screen to the drain pump.
Check and level, if necessary, the drain pump as well as
the ice maker.
Check the vent line for any restrictions or kinks and repair
as necessary.
Check the discharge line and connection to the desired
drain for any restrictions or kinks and repair as necessary.
The drain pump must be level. Check for level on the
top of the drain pump case and adjust the tubing or use
shims to level.