PAR. PROCEDURE SETTABLE VALUES
PROGRAMMING PROCEDURES
Positioning of operator 1
Positioning of operator 2
Memorization of the motors’ stroke
Deletion of transmitters
Transmitters memorizing
Search and deletion of a transmitter
Restoring the operating parameters
Lock access to programming
How to learn connected DE@NET devices (unused at the moment)
Restoring the “I/O” con! gurations (input/output)
Downloading data on the external memory unit
Uploading data  from an external memory unit
Visualisation of inputs and operations-counter status
Unused parameter
Unused parameter
PAR. PARAMETER DESCRIPTION SETTABLE VALUES
DEFAULT VALUES
24V
INPUTS CONFIGURATION PARAMETERS
INPUT_3  selectioning input type
• 000: IN3 type=free contact
• 001: IN3 type=constant resistance 8K2
Unused parameter
• 000: NONE (unused parameter)
• 001: START (start)
• 002: PED. (pedestrian)
• 003: OPEN (separated open)
• 004: CLOSE (separated close)
• 005: OPEN_PM (man present open)
• 006: CLOSE_PM (man present close)
• 007: ELOCK_IN (con! gurable Output 2. See P062)
• 008: PHOTO 1 (photocell 1)
• 009: PHOTO 2 (photocell 2)
• 010: SAFETY 1 (safety rib 1)
• 011: STOP (lock)
• 012: FCA1 (opening limit switches Mot1)
• 013: Not Available
• 014: FCC1 (closing limit switches Mot1)
• 015: Not Available
• 016: SAFETY 2 (safety rib 2)
• 017: Not Available
• 018: Not Available
• 019: AUX_IN (con! gurable Output 1. See P066)
/
INPUT_1  operating selection IN1
INPUT_2  operating selection IN2
Unused parameter /
Unused parameter /
Unused parameter /