33
24V
INPUTS CONFIGURATION
PARAMETERS
Allocation of CHANNEL 1 of remotes
Warning: the OPEN_PM and CLOSE_PM
functions are not available with the HCR
Rolling Code set (P027=1)
• 000: NONE (unused parameter)
• 001: START (start)
• 002: PEDESTRIAN (pedestrian)
• 003: OPEN (separated open)
• 004: CLOSED (separated close)
• 005: OPEN_PM (man present open)
• 006: CLOSED_PM (man present close)
• 007: ELOCK_IN (con! gurable Output 2. See P062)
• 008: AUX_IN (con! gurable Output 1. See P066)
CH1
Allocation of CHANNEL 2 of remotes CH2
Allocation of CHANNEL 3 of remotes CH3
Allocation of CHANNEL 4 of remotes CH4
Selection of type of remotes
• 000: HCS ! x-code
• 001: HCS rolling-code
• 002: Dip-switch
OPERATORS CONFIGURATION
PARAMETERS
Selection type of operators
• 000: ADVANCE
Unused parameter
Unused parameter
OPERATING PARAMETERS
Operators speed adjustment during slow-down while opening
Warning: by modifying the values of these
parameters, on exiting the programming
mode, a new learning of the motor stroke
will be requested.
15%tot........................100%tot
Operators speed adjustment during the stroke while opening 15%tot........................100%tot
Operators speed adjustment during the stroke while closing 15%tot........................100%tot
Operators speed adjustment during slow-down while closing 15%tot........................100%tot
Slow down duration adjustment while opening 0%tot............................80%tot
Slow down duration adjustment while closing 0%tot............................80%tot
Operator 1 force adjustment while opening
(if = 100% obstacle detection deactivated)
1%tot…...........................100%tot
Operator n.1 force adjustment while closing
(if = 100% obstacle detection deactivated)
1%tot…...........................100%tot
Unused parameter
Unused parameter
Automatic closing times adjustment
(if = 0 automatic closing deactivated)
0sec...................................255sec
Pedestrian automatic closing time adjustment
(se = 0 pedestrian automatic closing deactivated)
0sec...................................255sec
Pedestrian stroke duration adjustment 5%tot…...........................50%tot
Pre-" ashing time adjustment 0sec…….10sec
Unused parameter
Unused parameter