35
24V
OPERATING PARAMETERS
Unused parameter
Multiplier operations-counter: Multiply the number of operations after which the total operations-counter will be updated.
To view the values, refer to the section “Visualisation of inputs and operations-counter status”.
• 000: “x100
• 001: “x1000
• 002: “x10000
• 003: “x100000
Maintenance Operations-counter: if = 0 reset the counter and disables the intervention request , if> 0 indicates the number
of operations (x 500) to be made before the control panel executes a 4 second additional pre-! ash to indicate the need of
maintenance.
i.g.: If P065 = 050, operations number = 50x500 = 25000 operations
Warning: Before you set a new value of the counter-manoeuvres maintenance, the same must be reset by setting P065= 0 and
only later P065 = “new value”.
• 000: “Request Maintenance disabled
• >000: “Number of operations (x 500) for required maintenance
(1...................................255)
OUTPUT_1 functioning selection:
If=1 " xed ! ashing output (for ! ashing lights with internal intermittent circuit); If=2 intermittent ! ashing output; If=3 Fixed open
gate LED” (output always On when the gate is open, OFF at the end of a closure manoeuvre); If=4 Intermittent open gate LED”
(slow intermittent output during opening and fast during closing, always ON with gate open, always OFF only at the end of a closing
manoeuvre); If=5 Courtesy light” (output ON during every movement, OFF when the motor stops, after the delay set); If=6 24V
output for electric lock in " xed mode; If=7 24V output for electric lock in inverted mode; If=8 output for accessories power supply;
If=9 24V output commanded by AUX_IN input in impulse mode; If=10 24V output commanded by AUX_IN input in bistable mode;
If>10 24V output commanded by AUX_IN input in timed mode (the value set indicates the switch-off delay in seconds).
Warning: If P066=8, output functioning is determined by the functioning envisioned in parameters P061 (Energy Saving) and
P071 (Safety devices autotest).
• 001: “" xed ! ashing output
• 002: “intermittent ! ashing output
• 003: “Fixed open gate LED
• 004: “Intermittent open gate LED
• 005: “Courtesy light (switching off delay set from P052)
• 006: “24V
" xed electric lock output max 5W
• 007: “24V
inverted electric lock output max 5W
• 008: “24V
accessories power supply output max 5W
• 009: “24V
impulse mode output max 5W
• 010: “24V
bistable mode output max 5W
• >010: “24V
temporized output max 5W
(11sec………………255sec)
SAFETY 1
Operation of the SFT input: if = 0 safety edge always enabled, if = 1 safety edge enabled only while closing, if = 2
safety edge enabled only while closing and before any movement, if = 3 safety edge enabled only when opening, if
= 4 safety edge enabled only while opening and before any movement; as for the obstacle detection with internal
anti-crushing sensor, also the activation of the inputs SFT1 and SFT2 causes the complete or partial reversal as
set by P055 (duration of inversion on obstacles while opening, and P056 (duration of reversal on obstacle while
closing)
• 000: “safety edge always enabled
• 001: “safety edge enabled only while closing
• 002: “safety edge enabled only while closing and before any movement
• 003: “safety edge enabled only when opening
• 004: “safety edge enabled only while opening and before any movement
SAFETY 2
Unused parameter
Adjustment of acceleration durability
Warning: if soft start is activated, the acceleration is deactivated indipendently from P070 value.
• 000: “acceleration deactivated (it runs an acceleration of minimum durability,
almost imperceptible)
• 00X: “adjusts the acceleration durability at 1,5 sec (X*6 ms)
(1...................................255)
Safeties self-test: if = 0 24V output with autotest disabled; if = 1 24V output for safeties with self-test (it turn the output off and
check the contact opening before each maneuver).
Warning: In order to work in self-test mode, all devices must be connected to the con" gurable 24V output (6-7 for OUTPUT_1) (13-
14 for OUTPUT_2) with P062 and/or P066 = 8, and be wired and aligned before the motor stroke learning (P003).
• 000: “net power supply (safeties self-test disabled)
• 001: “safeties self-test enabled
Unused parameter
Unused parameter
Unused parameter
Unused parameter