G E K O
20
PAR. PROCEDURE SETTABLE VALUES
PROGRAMMING PROCEDURES
Positioning of operator 1
Positioning of operator 2
Memorization of the motors’ stroke
Deletion of transmitters
Transmitters memorizing
Search and deletion of a transmitter
Loading of standard parameters: the list is up dated with factory settings
DEA_NET net learning (not available at the moment)
PAR. PARAMETER DESCRIPTION SETTABLE VALUES
DEFAULT VALUES
(for different standards
of installation)
Swing gate
INPUTS CONFIGURATION PARAMETERS
INPUT_3 selectioning input type •000:IN3type=freecontact
•001:IN3type=constantresistance8K2
 (free contact)
INPUT_1 operating selection •000:NONE(unusedparameter)
•001:START(start)
•002:PED.(pedestrian)
•003:OPEN(separatedopen)
•004:CLOSE(separatedclose)
•005:OPEN_PM(manpresentopen)
•006:CLOSE_PM(manpresentclose)
•007:PHOTO(photocell)
•008:SAFETY(safetyrib)
•009:STOP(lock)
•010:FCA1(openinglimitswitchesMot1)
•011:FCA2(openinglimitswitchtesMot2)
•012:FCC1(closinglimitswitchesMot1)
•013:FCC2(closinglimitswitchesMot2)
IN1
 (START)
INPUT_2 operating selection IN2
 (PHOTO)
INPUT_3 operating selection IN3
 (STOP)
INPUT_4 operating selection IN4
 (PED)
INPUT_5 operating selection IN5
 (NONE)
Allocation of CHANNEL 1 of remotes •000:NONE(unusedparameter)
•001:START(start)
•002:PEDESTRIAN(pedestrian)
•003:OPEN(separatedopen)
•004:CLOSED(separatedclose)
•005:OPEN_PM(manpresentopen)
•006:CLOSED_PM(manpresentclose)
CH1
 (START)
Allocation of CHANNEL 2 of remotes CH2
 (NONE)
Allocation of CHANNEL 3 of remotes CH3
 (NONE)
Allocation of CHANNEL 4 of remotes CH4
 (NONE)
Selection of type of remotes •000:HCSfix-code
•001:HCSrolling-code
•002:Dip-switch
OPERATORS 
CONFIGURATION 
PARAMETERS
Selectioning operators number •001:oneoperator
•002:twooperators
Selected work with or without encoders. 
CAUTION: Remember to correctly set the jumpers J5 and J9 (see table 1)
WARNING: J5, J9 and P021 must be set correctly before performing the procedure for programming
•000:motorswithencoder
•001:engineswithoutencoder