RESPONSIBILITIESOFTHEINSTALLER
Remember thatanyonewho sells and/ormotorisesdoors/gates becomes themanufacturerof the automaticdoor/gate
machineandmustthereforeprepareandconserveatechnicalfolderthatcontainsthefollowingdocuments(seeMachinery
DirectiveEnclosureV):
• Assemblydrawingoftheautomaticdoor/gate;
• Electricalconnectionandcontrolcircuitwiringdiagram;
• Riskanalysisincluding:alistoftheessentialsafetyrequirementsprovidedinMachineryDirectiveEnclosureI;alistoftherisks
posedbythedoor/gateandthedescriptionofthesolutionsadopted.
• Keeptheseoperatinginstructionsinasafeplacetogetherwiththeinstructionsforalltheothercomponents;
• Preparetheseoperatinginstructionsandgeneralsafetywarnings(forthecompletionoftheseoperatinginstructions)and
deliveracopytothefinaluser;
• Filloutthemaintenanceregisteranddeliveracopytothefinaluser;
• FilloutthecompleteCElabelorplateandapplyittothedoor/gate.
Note:Thetechnicalfoldermustbeconservedforinspectionbythecompetentnationalauthoritiesforatleasttenyearsfrom
thedateconstructionoftheautomaticdoor/gate.
OPERATING CONTROL” table
Type of use
Type of control
Informed users
(private areas)
Informed users
(public areas)
Uninformed users
Person-present control Pushbutton control Pushbutton control with key
The person-present control is
not possible
Pulse control with the gate in
sight
Force limitation
or
presence detectors
Force limitation
or
presence detectors
Force limitation
and photocells
or presence detectors
Pulse control with the gate
not in sight
Force limitation
or
presence detectors
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
Automatic control
(i.e. control with
timed closing)
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
Force limitation
and photocells
or presence detectors
“EXAMPLE OF TYPICAL INSTALLATION” picture
Pos. Description
1 1Pilly 60 column
2 LIVI
3 104 Lux series
photocells
4 Safety edge
5 Lumy flashing light
6 Remote-control
7 102 Lux key selector
1 4 5 6 7
2 3