61
BARRIERS
8.2 Learning
1. Scroll down the parameters with
and
keys until you visualise P005;
2. Confirm by pressing on the
key;
3. When the symbol
” flashes, press on
any key of the transmitter you want to mem-
orize;
4. The display visualizes the number of the
transmitter just memorized and then “
” flashing;
5. Memorize all necessary transmitters repeat-
ing this procedure from step 3;
6. Wait 10 seconds before quitting the memo-
rization mode, display shows now “----“.
Warning: In the case of rolling code remotes,
the receiver can be put into learning mode
by pressing the hidden button on a remote
control previously learned.
9 Adjustment of operating parameters
If you need to modify the operating parameters, follow the proce-
dure below.
Warning: In order to ensure an optimum operation, the para-
meters given in the table must be set as indicated for the type
of barrier used.
1. Scroll down the parameters until you visualize the desire pa-
rameter (i.g. P032);
2. Confirm by pressing on the
key;
3. By pressing on
and , set up the desired value;
4. Confirm by pressing on the
key (display shows the param-
eters previously selected).
For the complete list of the “Operating Parameters” See
the table on page. 66.
Recommended values for standard “TYPE 03 - Barriers”
BOOM
Running speed
(P032 - P033)
Slowdown speed
(P034)
Slowdown
duration
(P035 - P036)
Soft-start
(P054)
Facilitation
release
(P057)
Stop margin
(P058 - P059)
STOP
STOP_L (7,5 m) 65% 30% 30% 1 2 15
STOP_L (6 m) 80% 30% 30% 1 2 15
STOP_L (5 m) 90% 30% 30% 1 2 15
STOP_L (4 m) 90% 30% 30% 0 2 15
STOP_V (4 m) 100% 30% 30% 0 1 7
PASS
PASS_L (4 m) 100% 30% 30% 1 2 20
PASS_V (3 m) 100% 25% 35% 0 1 5
PASS_V (4 m) 85% 25% 30% 0 1 5
10 Programming complete
WARNING At the end of the programming procedure, use the buttons and until the appearance of the symbol “----”, the
operator is now ready again for new manoeuvres.
To perform any “Advanced Programming” operations (cancellation of the remotes, configuration inputs, etc. ..), see