Active
digital
position
readout
unit,
cont'd
Tool
radius
compensation
The
active
digital
readout
unit
permits
tool
radius
compen'
sations
with
the
aid
of
keys
(10).
This
requires
the input
of
the
cufter
diameter.
Proceed
in the
following
order:
-
Use
keyboard
(
l) to
key cutter
diameter
into
setpoint
readout
(5).
-
Operate
t.v
E
(10)
:
the
control
will calculate
the cut-
ter
radius.
This
will
then
appear
in
setpoint
readout
(5)
and
will
be
stored
automatically.
-
Key in
setpoint
on
keYboard
(l).
-
Operate
either
E
key
{10)
to add
cutter
radius
or
p
(
I
0)
to
subtract
cutter
radius
from
setpoint
value
(5).
-
When
operating
tool
compensation
keys twice,
the full
diameter
will
be
either
added
or
subtracted,
for example
for
machining
the
opposite
wall
of
a
pocket.
-
Transfer to actual-value
counters
and
automatic
position'
ing as
described
above.
Fault diagnosis
ln the event
of
faults or defects,
the active
digital
readout
unit
will automatically
give
diagnosis
readouts.
-
Measuring
system
defective:
associated
actual-value
counter
will
start
flashing.
To
cancel
diagnosis
readout,
switch off
power
supply,
remedy
fault
and restart
the unit-
-
Defect
in
electronics:
LEDs
above
reference
point
keys
will light
up.
To cancel
diagnosis
readout,
switch off
power
supply.
lf fault diagnosis
reappears
after
switching off
and on
again, return
digital readout
unit
for
repair
(state
LEDs
lighting
up).
-
Positioning
error:
if feed
control
lever
is moved
in
wrong
direction
for
a
selected
positioning
operation.
the
feed
motion
will be
switched off
after
200
pm.
Actual-readout
(7)
will
show
'u'symbols.
To
cancel
diagnosis
readout,
operate
E4
t.v, then rnove
feed
control
lever in correct
direction.
Caution
Never remove
or
insert
plugs
while
unit
is energized.
Additional
setup
and
maintenanpe
instructions,
as well as
examples
of operating
the
unit,
will be
found in the oper'
ator's manual
supplied
with
the digital
position
readout
unit.
Printed
in
the
Fedaral Republic
of Germany