Questions and Answers

  • M
    malonedorothyAug 15, 2025
    What to do if the SCB is not found on my DeDietrich EVODENS PRO Amc 45 Boiler?
    • A
      areillyAug 15, 2025
      If the SCB is not found in your DeDietrich Boiler, it might be due to a bad connection. Check the wiring and connectors. If the connections are secure, the SCB may be faulty and require replacement.
  • D
    Daniel BallardAug 18, 2025
    What to do if there is no flame during operation of my DeDietrich EVODENS PRO Amc 45?
    • J
      Jose BarryAug 18, 2025
      If you're experiencing no flame during operation with your DeDietrich Boiler, it could be due to a configuration error leading to no ionization current or poor combustion. Try purging the gas supply to remove air and ensure the gas tap is fully open. Check the gas supply pressure and the operation and setting of the gas valve unit. Also, verify that the air inlet and flue gas discharge flues are not blocked and that there is no recirculation of flue gases.
  • D
    Derek HernandezAug 21, 2025
    What to do if I see a water pressure warning on my DeDietrich Boiler?
    • C
      Christopher LiuAug 21, 2025
      If you receive a water pressure warning on your DeDietrich Boiler, it means the water pressure is too low. You should check the water pressure to resolve this issue.
  • K
    Kristina VargasAug 25, 2025
    How to troubleshoot an open outdoor temperature sensor on a DeDietrich Boiler?
    • A
      afordAug 26, 2025
      If the outdoor temperature sensor of your DeDietrich Boiler is open, it could be due to a bad connection. Check the wiring and connectors. Also, verify the sensor is correctly fitted and replace the sensor if it's faulty or not present.
  • R
    ryanlewisAug 28, 2025
    What to do if the outdoor sensor is not detected on my DeDietrich EVODENS PRO Amc 45 Boiler?
    • M
      Miguel OwensAug 28, 2025
      If the outdoor sensor is not detected by your DeDietrich Boiler, ensure the sensor is properly connected. If it's not connected, connect it. If it's connected incorrectly, correct the connection.
  • K
    Karla VillarrealAug 31, 2025
    What should I do if the water pressure sensor is not detected on my DeDietrich EVODENS PRO Amc 45?
    • M
      Michael RivasAug 31, 2025
      If the water pressure sensor is not detected by your DeDietrich Boiler, make sure the sensor is properly connected. If it is not connected, connect it. If it is connected, ensure it is connected correctly.
  • L
    Lauren GrantSep 4, 2025
    What should I do if the SCB is not found and the manual says to do an auto-detect on my DeDietrich EVODENS PRO Amc 45?
    • F
      frylindaSep 4, 2025
      If the SCB is not found on your DeDietrich Boiler, carry out an auto-detect.
  • S
    Susan ObrienSep 7, 2025
    How to fix the 'SCB not found' error on my DeDietrich Boiler?
    • L
      laura13Sep 7, 2025
      If the SCB is not found on your DeDietrich Boiler, perform an auto-detect to resolve the issue.
  • R
    Rebecca WardSep 12, 2025
    What is the solution if the SCB is not found on my DeDietrich Boiler?
    • O
      oneillericSep 12, 2025
      If your DeDietrich Boiler indicates that the SCB is not found, the solution is to carry out an auto-detect.

DeDietrich EVODENS PRO Amc 45 Specifications

General IconGeneral
TypeCondensing Boiler
Power Output45 kW
FuelGas
Sound Power Level52 dB(A)
Warranty2 years
Fuel TypeNatural Gas
EfficiencyUp to 109%
Output Range45 kW