MPX 24 COMPACT
MPX 20/24 MI COMPACT
MPX 24/28 MI COMPACT
MPX 28/33 MI COMPACT
en CONDENSING GAS WALL-HUNG BOILERS
Instructions manual for users and tters
pl NAŚCIENNY GAZOWY KOCIOŁ KONDENSACYJNY
Instrukcja obsługi dla użytkowników i instalatorów
cs PLYNOVÝ ZÁVĚSNÝ KONDENZAČNÍ KOTEL
Návod na použití určený pro uživatele a instalatéra
sk PLYNOVÝ ZÁVESNÝ KONDENZAČNÝ KOTOL
Návod na použitie určený pre používateľa a inštalatéra
fr CHAUDIERES MURALES A GAZ A CONDENSATION
Notice d’emploi et d’installation destinée à l’usager et à l’installateur
ro CENTRALĂ TERMICĂ MURALĂ CU CONDENSARE, PE GAZ
Manual de instrucţiuni destinat utilizatorului şi instalatorului
el ΕΠΙΤΟΙΧΙΟΣ ΛΕΒΗΤΑΣ ΑΕΡΙΟΥ ΣΥΜΠΥΚΝΩΣΗΣ
Εγχειρίδιο χρήσης για τον χρήστη και τον εγκαταστάτη
ru НАСТЕННЫЙ ГАЗОВЫЙ КОНДЕНСАЦИОННЫЙ КОТЕЛ
Паспорт изделия. Руководство по установке и эксплуатации

Questions and Answers

  • W
    wzunigaSep 9, 2025
    What to do if my DeDietrich MPX 24/28 MI COMPACT Boiler has incorrect power supply frequency?
    • A
      Alicia LewisSep 9, 2025
      If your DeDietrich Boiler displays an incorrect power supply frequency, check whether the issue originates outside the boiler. If so, contact the power supply company.
  • S
    Samantha JohnsonAug 23, 2025
    What to do if my DeDietrich MPX 24/28 MI COMPACT Boiler ignition fails after 5 attempts?
    • M
      Mr. Michael DavisAug 23, 2025
      If your DeDietrich Boiler fails to ignite after 5 attempts, check if the gas valve is open and that there is no air in the gas supply circuit. Verify the gas supply pressure and ensure the wire is uninterrupted, making good contact with the flame sensing electrode and the ignition switch. Check correct operation of the condensate drainage.
  • T
    thomas33Aug 25, 2025
    What causes a DeDietrich MPX 24/28 MI COMPACT to lose flame at ignition?
    • V
      Virginia MortonAug 25, 2025
      A loss of flame at ignition in your DeDietrich Boiler may be due to the flame sensing electrode being in poor condition or incorrectly positioned. Check the wire to ensure it is uninterrupted and makes good contact with the flame sensing electrode and the ignition switch. Also, check for any recirculation of fumes.
  • S
    Shawn GrayAug 27, 2025
    What to do if the safety thermostat tripped on my DeDietrich MPX 24/28 MI COMPACT Boiler?
    • T
      Thomas BartlettAug 27, 2025
      If the safety thermostat on your DeDietrich Boiler tripped due to overtemperature (likely caused by a blocked pump or air in the heating circuit), check the pump operation and the pump power input wiring. Also, check that the limit thermostat is undamaged and replace it if necessary, and verify the continuity of the limit thermostat wiring.
  • B
    Benjamin MorrisonAug 27, 2025
    What to do if my DeDietrich MPX 24/28 MI COMPACT Boiler shows a gas valve control error?
    • A
      Amanda BruceAug 28, 2025
      If your DeDietrich Boiler shows a gas valve control error, check the connections between the gas valve and the electronic board. If necessary, replace the electronic board.
  • T
    Thomas JacksonAug 29, 2025
    What causes a DeDietrich MPX 24/28 MI COMPACT gas valve to be blocked?
    • W
      William PittsAug 29, 2025
      A blocked gas valve in your DeDietrich Boiler may be due to an issue with the gas supply pressure or the integrity and position of the sensing and ignition electrodes and their wiring. If necessary, replace the electronic board.
  • L
    lisamaldonadoSep 18, 2025
    How to troubleshoot a communication problem between the boiler board and control unit in a DeDietrich MPX 24/28 MI COMPACT?
    • A
      amyclementsSep 18, 2025
      To troubleshoot a communication problem between the boiler board and control unit, check the wiring between the Ambient Unit and the electronic board or RF link.
  • S
    Sheryl ReeseSep 18, 2025
    How do I calibrate the electronic board on my DeDietrich MPX 24/28 MI COMPACT Boiler?
    • C
      Carly NewmanSep 18, 2025
      To calibrate the electronic board on your DeDietrich Boiler, activate the automatic calibration function described in the spare parts instructions sheet.
  • E
    edelgadoSep 7, 2025
    What does it mean if my DeDietrich Boiler has an internal board error?
    • T
      Tonya WadeSep 7, 2025
      If your DeDietrich Boiler indicates an internal board error, replace the electronic board.
  • M
    Melissa AllenSep 4, 2025
    What to do if my DeDietrich Boiler shows a gas valve connection error?
    • H
      Helen SimmonsSep 4, 2025
      If your DeDietrich Boiler shows a gas valve connection error, check the connections between the gas valve and the electronic board.

Summary

Safety Warnings

Gas and Combustion Fumes Safety

Provides critical safety instructions for detecting and responding to smells of gas or combustion fumes.

Flammable Material Handling

Advises against storing flammable materials near the boiler.

Boiler Servicing and Cleaning Precautions

Emphasizes switching off the boiler before any maintenance or cleaning operations.

General Precautions

Commissioning the Boiler

Boiler Startup Procedure

Step-by-step guide for initial boiler lighting and powering.

Prolonged Shutdown and Anti-Freeze Protection

Gas Conversion

Faults

Fault Code Identification and Reset

Explains how fault codes are displayed and how to reset minor faults.

Fault Code Directory

Lists specific fault codes, their descriptions, and recommended actions.

Filling the System

Routine Maintenance Instructions

Instructions Prior to Installation

Installing the Boiler

Boiler Mounting and Connections

Details the process of locating, fixing, and connecting the boiler to the system.

Installing the Ducts

Concentric Duct Installation

Explains the use and installation of concentric flue-air ducts, including bends and lengths.

Electrical Connections

Power Supply and Wiring Safety

Details safe electrical connection to the mains, including cable type and fuses.

Terminal Block M1 and M2 Usage

Explains the function and connection points for terminal blocks M1 (high voltage) and M2 (low voltage).

Room Thermostat Connection

Provides step-by-step instructions for connecting a room thermostat to the boiler.

Special Functions

Initial Boiler Ignition Procedure

Details the sequence for the first-time lighting and gas recognition of the boiler.

Combustion Test and Adjustment (CO2)

Covers performing combustion tests and adjusting CO2 levels for optimal performance.

Parameters Setting

Accessing and Modifying Parameters

Explains how to enter the parameter menu and change settings using the control buttons.

Troubleshooting Service Faults

Fault Diagnosis and User Reset

Guides users on interpreting fault codes, resetting the boiler, and when to call service.

Adjustment and Safety Devices

Annual Servicing

DeDietrich MPX 24/28 MI COMPACT Specifications

General IconGeneral
ModelMPX 24/28 MI COMPACT
CategoryBoiler
TypeCondensing
Fuel TypeNatural Gas / LPG
InstallationWall-mounted
DHW ProductionInstantaneous
Modulation1:7
Dimensions700 x 400 x 300 mm
Weight32 kg
Max working pressure3 bar
DHW flow rate at ΔT 30°C11.4 l/min
Flue diameter60/100 mm
Electrical connection230 V / 50 Hz
Protection ratingIPX4D
Heat output (kW)24 kW
DHW output (kW)28 kW
Output24 kW (heating), 28 kW (DHW)