MPX 24 COMPACT
MPX 20/24 MI COMPACT
MPX 24/28 MI COMPACT
MPX 28/33 MI COMPACT
en CONDENSING GAS WALL-HUNG BOILERS
Instructions manual for users and tters
pl NAŚCIENNY GAZOWY KOCIOŁ KONDENSACYJNY
Instrukcja obsługi dla użytkowników i instalatorów
cs PLYNOVÝ ZÁVĚSNÝ KONDENZAČNÍ KOTEL
Návod na použití určený pro uživatele a instalatéra
sk PLYNOVÝ ZÁVESNÝ KONDENZAČNÝ KOTOL
Návod na použitie určený pre používateľa a inštalatéra
fr CHAUDIERES MURALES A GAZ A CONDENSATION
Notice d’emploi et d’installation destinée à l’usager et à l’installateur
ro CENTRALĂ TERMICĂ MURALĂ CU CONDENSARE, PE GAZ
Manual de instrucţiuni destinat utilizatorului şi instalatorului
el ΕΠΙΤΟΙΧΙΟΣ ΛΕΒΗΤΑΣ ΑΕΡΙΟΥ ΣΥΜΠΥΚΝΩΣΗΣ
Εγχειρίδιο χρήσης για τον χρήστη και τον εγκαταστάτη
ru НАСТЕННЫЙ ГАЗОВЫЙ КОНДЕНСАЦИОННЫЙ КОТЕЛ
Паспорт изделия. Руководство по установке и эксплуатации

Questions and Answers

  • D
    daviesrickySep 9, 2025
    What to do if my DeDietrich MPX 24 COMPACT Boiler has incorrect power supply frequency?
    • P
      Patricia Campbell DDSSep 9, 2025
      If your DeDietrich Boiler displays an incorrect power supply frequency, check whether the issue originates outside the boiler. If so, contact the power supply company.
  • L
    lopezjamesAug 23, 2025
    What to do if my DeDietrich MPX 24 COMPACT Boiler ignition fails after 5 attempts?
    • B
      Brenda GarciaAug 23, 2025
      If your DeDietrich Boiler fails to ignite after 5 attempts, check if the gas valve is open and that there is no air in the gas supply circuit. Verify the gas supply pressure and ensure the wire is uninterrupted, making good contact with the flame sensing electrode and the ignition switch. Check correct operation of the condensate drainage.
  • D
    David TurnerAug 25, 2025
    What causes a DeDietrich MPX 24 COMPACT Boiler to lose flame at ignition?
    • J
      Judith JacksonAug 25, 2025
      A loss of flame at ignition in your DeDietrich Boiler may be due to the flame sensing electrode being in poor condition or incorrectly positioned. Check the wire to ensure it is uninterrupted and makes good contact with the flame sensing electrode and the ignition switch. Also, check for any recirculation of fumes.
  • J
    Jason BooneAug 26, 2025
    What to do if the safety thermostat tripped on my DeDietrich MPX 24 COMPACT?
    • F
      Felicia SmithAug 26, 2025
      If the safety thermostat on your DeDietrich Boiler tripped due to overtemperature (likely caused by a blocked pump or air in the heating circuit), check the pump operation and the pump power input wiring. Also, check that the limit thermostat is undamaged and replace it if necessary, and verify the continuity of the limit thermostat wiring.
  • G
    George WilliamsAug 27, 2025
    What to do if my DeDietrich MPX 24 COMPACT shows a gas valve control error?
    • B
      Barry StoneAug 27, 2025
      If your DeDietrich Boiler shows a gas valve control error, check the connections between the gas valve and the electronic board. If necessary, replace the electronic board.
  • G
    gregorycalderonAug 29, 2025
    What causes a DeDietrich MPX 24 COMPACT gas valve to be blocked?
    • R
      Randall HollandAug 29, 2025
      A blocked gas valve in your DeDietrich Boiler may be due to an issue with the gas supply pressure or the integrity and position of the sensing and ignition electrodes and their wiring. If necessary, replace the electronic board.
  • J
    Jordan HillSep 18, 2025
    How to troubleshoot a communication problem between the boiler board and control unit in a DeDietrich MPX 24 COMPACT?
    • B
      Barbara AndersonSep 18, 2025
      To troubleshoot a communication problem between the boiler board and control unit, check the wiring between the Ambient Unit and the electronic board or RF link.
  • S
    sanchezpatrickSep 18, 2025
    How do I calibrate the electronic board on my DeDietrich Boiler?
    • B
      Brady HughesSep 22, 2025
      To calibrate the electronic board on your DeDietrich Boiler, activate the automatic calibration function described in the spare parts instructions sheet.
  • F
    Frank ButlerSep 7, 2025
    What does it mean if my DeDietrich Boiler has an internal board error?
    • E
      Erica FosterSep 7, 2025
      If your DeDietrich Boiler indicates an internal board error, replace the electronic board.
  • M
    matthewfordSep 4, 2025
    What to do if my DeDietrich Boiler shows a gas valve connection error?
    • D
      Dr. Amber JacobsonSep 4, 2025
      If your DeDietrich Boiler shows a gas valve connection error, check the connections between the gas valve and the electronic board.

Summary

SAFETY WARNINGS

SMELL OF GAS

Instructions for handling situations involving the smell of gas to ensure safety.

SMELL OF COMBUSTION FUMES

Procedures to follow if there is a smell of combustion fumes for occupant safety.

FLAMMABLE MATERIAL

Guidance on the safe storage and use of flammable materials near the boiler.

GENERAL PRECAUTIONS

ENERGY-SAVING TIPS

ADJUSTMENT IN HEATING MODE

Tips for optimizing heating water flow temperature and room temperature for energy efficiency.

DOMESTIC HOT WATER

Advice on setting domestic hot water temperature to save energy and reduce scale.

COMMISSIONING THE BOILER

ADJUSTING CH AND DHW FLOW TEMPERATURE

Guide to setting the central heating and domestic hot water flow temperatures.

OPERATING MODES

Explanation of how to enable DHW, Heating or Heating Only modes on the appliance.

PROLONGED SHUTDOWN AND ANTI-FREEZE PROTECTION

GAS CONVERSION

FAULTS

BOILER INFORMATION MENU

SWITCHING OFF THE BOILER

FILLING THE SYSTEM

ROUTINE MAINTENANCE INSTRUCTIONS

INSTRUCTIONS PRIOR TO INSTALLATION

SOLAR WARNING

Cautionary note about the maximum temperature of domestic hot water when connected to solar panels.

INSTALLING THE BOILER

CONTENTS OF PACK

List of items included in the boiler packaging for installation.

BOILER DIMENSIONS AND GAS WATER CONNECTIONS

Details on the boiler's physical dimensions and connection points for gas and water.

INSTALLING THE DUCTS

CONCENTRIC DUCTS

Installation guidelines for coaxial flue and air ducts, including bend allowances.

SEPARATE DUCTS

ELECTRICAL CONNECTIONS

CONNECTING THE ROOM THERMOSTAT

Step-by-step guide for wiring a room thermostat to the boiler's terminal block M1.

ACCESSORIES NOT INCLUDED IN THE SUPPLY

Information on optional accessories like external sensors and their connection.

SPECIAL FUNCTIONS

INITIAL IGNITION

Procedure for the first-time lighting of the boiler, including gas recognition and system venting.

SYSTEM GAS EXTRACTION FUNCTION

How to use the function to remove air from the heating circuit after installation or maintenance.

CHIMNEY SWEEPER

Enables maximum heating power for boiler testing and adjustment.

COMBUSTION TEST (CO₂)

COMBUSTION ADJUSTMENT FUNCTION (CO2%)

GAS VALVE

GAS CONVERSION METHODS

Information on converting the boiler between natural gas and LPG by authorized personnel.

PARAMETERS SETTING

ADJUSTING MAXIMUM HEATING POWER

TROUBLESHOOTING SERVICE FAULTS

ADJUSTMENT AND SAFETY DEVICES

PUMP CAPACITY;HEAD

ANNUAL SERVICING

COMBUSTION PARAMETERS

How to measure and check combustion efficiency and toxicity of flue gas products.

HYDRAULIC UNIT

Details on the hydraulic unit, including components and filter cleaning.

POSITIONING THE ELECTRODES

REPLACEMENT OF PARTS

DISMANTLING, DISPOSAL AND RECYCLING

TECHNICAL SPECIFICATIONS

TECHNICAL PARAMETERS

PRODUCT FICHE

DeDietrich MPX 24 COMPACT Specifications

General IconGeneral
BrandDeDietrich
ModelMPX 24 COMPACT
CategoryBoiler
LanguageEnglish