21
INSTALLER Section (en)
7679433.01 (3-06/17)
21. TECHNICAL PARAMETERS
DE DIETRICH MPX
24
COMPACT
20/24 MI
COMPACT
24/28 MI
COMPACT
28/33 MI
COMPACT
Condensing boiler
Yes Yes Yes Yes
Low-temperature boiler
(1)
No No No No
B1 boiler
No No No No
Cogeneration space heater
No No No No
Combination heater
No Yes Yes Yes
Rated heat output
Prated
kW 24 20 24 28
Useful heat output at rated heat output
and high temperature regime
(2)
P
4
kW 24.0 20.0 24.0 28.0
Useful heat output at 30% of rated heat
output and low temperature regime
(1)
P
1
kW 8.0 6.7 8.0 9.4
Seasonal space heating energy efficiency
ƞ
s
% 93 93 93 93
Useful efficiency at rated heat output and
high temperature regime
(2)
ƞ
4
% 87.9 88.0 87.9 88.1
Useful efficiency at 30% of rated heat
output and low temperature regime
(1)
ƞ
1
% 98.0 98.0 98.0 98.1
Auxiliary electricity consumption
Full load
elmax
kW 0.042 0.030 0.042 0.041
Part load
elmin
kW 0.013 0.013 0.013 0.013
Standby mode
P
SB
kW 0.003 0.003 0.003 0.003
Other items
Standby heat loss
P
stby
kW 0.035 0.035 0.035 0.040
Ignition burner power consumption
P
ign
kW 0.000 0.000 0.000 0.000
Annual energy consumption
Q
HE
GJ
74 62 74 87
Sound power level, indoors
L
WA
dB 52 49 48 53
Emissions of nitrogen oxides
NO
X
mg/kWh 16 15 17 15
Domestic hot water parameters
Declared load profile
XL XL XXL
Daily electricity consumption
Q
elec
kWh 0.162 0.232 0.214
Annual electricity consumption
AEC
kWh 36 51 47
Water heating energy efficiency
ƞ
wh
% 88 86 87
Daily fuel consumption
Q
fuel
kWh 21.780 22.470 27.820
Annual fuel consumption
AFC
GJ 17 17 22
(1) Low temperature means for condensing boilers 30°C, for low temperature boilers 37°C and for other heaters 50°C return temperature
(at heater inlet).
(2) High temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet.