EasyManua.ls Logo

DeDietrich MUSE40-2 - Installation of the Indoor Unit

DeDietrich MUSE40-2
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20181270 CR v8-2019Page 29
Outdoor unit dimensions and minimum distances to be respected on installation:
A
B
C
D
E
F
G
MUSE 40-2
mm
100
315
2000
545
300
800
500
MUSE 50-2
mm
100
315
2000
545
300
800
500
MUSE 60-3
mm
100
328
2000
655
300
834
500
MUSE 80-3
mm
100
328
2000
655
300
834
500
MUSE 100-4
mm
100
395
2000
805
300
985
500
MUSE 120-5
mm
100
395
2000
805
300
985
500
Dimensions for mounting feet on outdoor units:
Installation of the indoor unit
- Take into account the air distribution of the indoor unit in the building or room to be air-conditioned and select a
suitable location to obtain a uniform air temperature.
- Ensure that there are no sources of heat and/or fumes near the indoor unit
- Choose the correct location for installing the indoor units, taking into account the noise levels of each product
(e.g. bedroom)
- Do not install the appliance near doors and/or windows.
MODEL
A (mm)
B (mm)
MUSE 40-2
545
315
MUSE 50-2
545
315
MUSE 60-3
540
335
MUSE80-3
540
335
MUSE100-4
675
410
MUSE125-5
675
410
Air inlet
Left-hand mounting
feet
Right-hand mounting
feet
Air outlet