38
11 Troubleshooting guide
Record is not aligned
properly
Record does not get wet
Record is not aligned
properly
Record does not get wet
Thick records get stuck
When the record in the machine tilts
to one side and rubs again the
rubber gasket that is around the
record inseion slot, then mo likely
there is a problem with the align-
ment of the plaic rollers located
at the top right side of the machine
that revolve the record.
To solve the issue, remove the
rubber gasket from around the
record inseion slot. Use a large
flat headed screwdriver to shi the
roller on the top right side of the
machine on its sha slightly. The
sha of this roller is connected to a
motor driving the belt drive and the
roller has been placed on the sha
with a tight fit. It is possible to move
the roller’s position slightly by press-
ing on its sides with a screwdriver.
Before inseing anything into the
On some occasions, during the
washing cycle, the side of the
record exiting the ultrasonic clean-
ing tank can look almo dry. The
cleaning fluid acting as a sur-
factant together with the back and
foh movement of the record can
cause almo all the water to flow
o. When the water level inside the
ultrasonic cleaning tank is close to
the label during washing, then there
is no reason to be alarmed.
Degritter make sure that the device
has been turned o from the AC
switch at the back and also detach
the power cable from the machine.