19
9.1 Temperature
Ambient air temperatures for charge and discharge are indicated in the battery line technical specifications for each model below. These temperatures
correspond to the range at which a battery can continuously charge or discharge without derating current. For all batteries, the storage temperature
should be between 0° to 45°C (32° to 113°F).
9.2 Battery Specification Table – Traditional Battery Line
9.3 Battery Specification Table – High Performance Line
UL listing status will be updated in this manual as the products complete testing. A complete offering of UL listed products may be found by searching for
the UL file MH61859 at https://iq.ulprospector.com
9: PRODUCT LIMITATIONS / SPECIFICATIONS
Deka Ready Power Traditional Battery Line (2/3 Contactor) - Technical Specifications
24v 525AH 36v 550AH “A” 36v 550AH “B” 36V 700AH 48V 550AH 48V 700AH 48V 1050AH
Pack Part Number 03-930-0085 03-930-0258 03-930-0640 03-930-0015 03-930-0086 03-930-0298 03-930-0185
Pack Nominal Voltage (VDC) 25.6 38.4 38.4 38.4 51.2 51.2 51.2
Pack Min Voltage (VDC) 20 30 30 30 40 49 49
Pack Max Voltage (VDC) 28.8 38.4 38.4 38.4 58.4 55.3 55.3
Pack Capacity (AH) 525 550 550 700 550 700 1050
Pack Energy (0-100SOC) WH 13,440 21,120 21,120 26,880 28,160 35,840 53,760
Max Start Charge (Amps) 500 500 500 500 500 500 500
Max Continuous Discharge (Amps) 340A 340A 340A 340A 340A 340A 340A
Max Continuous Charge (Amps) 340A 340A 340A 340A 340A 340A 340A
Max Discharge Current (Amps) 340 rated 340 rated 340 rated 340 rated 340 rated 340 rated 340 rated
Max Charging Current (Amps) 340 rated 340 rated 340 rated 340 rated 340 rated 340 rated 340 rated
Max 10 Second Pulse Regen Charge
(Amps)
1000 1000 1000 1000 1000 1000 1000
Max 10 Second Pulse Regen
Discharge (Amps)
1000 1000 1000 1000 1000 1000 1000
Ambient Temperature - Charge
5° to 45° C
41° to 113° F
5° to 45° C
41° to 113° F
5° to 45° C
41° to 113° F
5° to 45° C
41° to 113° F
5° to 45° C
41° to 113° F
5° to 45° C
41° to 113° F
5° to 45° C
41° to 113° F
Ambient Temperature - Discharge
0° to 50° C
32° to 122° F
0° to 50° C
32° to 122° F
0° to 50° C
32° to 122° F
0° to 50° C
32° to 122° F
0° to 50° C
32° to 122° F
0° to 50° C
32° to 122° F
0° to 50° C
32° to 122° F
UL Listing – File
Number MH61859
US & Canada US & Canada – US & Canada US & Canada US & Canada –
Deka Ready Power High Performance Line (2/3 Contactor) – Technical Specifications
24v 525AH 36v 550AH “A” 36v 550AH “B” 36V 700AH 48V 550AH 48V 700AH 48V 1050AH
Pack Part Number 03-930-0576 03-930-0500 03-930-0635 03-930-0579 03-930-0502 03-930-0501 03-930-0683
Pack Nominal Voltage (VDC) 25.6 38.4 38.4 38.4 51.2 51.2 51.2
Pack Min Voltage (VDC) 24.7 36 36 36 48 48 48
Pack Max Voltage (VDC) 28.6 43.2 43.2 43.2 57.6 5 7.6 57.6
Pack Capacity (AH) 525 550 550 700 550 700 1050
Pack Energy (0-100SOC) WH 13,440 21,120 21,120 26,880 28,160 35,840 53,760
Max Start Charge (Amps) 500 500 500 500 500 500 500
Max Continuous Discharge (Amps) 350A 350A 350A 350A 350A 350A 350A
Max Continuous Charge (Amps) 350 350 350 350 350 350 350
Max Discharge Current (Amps) 380 limited 380 limited 380 limited 380 limited 380 limited 380 limited 380 limited
Max Charging Current (Amps) 380 limited 380 limited 380 limited 380 limited 380 limited 380 limited 380 limited
Max 30 Second Pulse - Charge
(Amps)
1200 1200 1200 1200 1200 1200 1200
Max 30 Second Pulse - Discharge
(Amps)
1200 1200 1200 1200 1200 1200 1200
Max 1 Second Pulse - Discharge
(Amps)
1500 1500 1500 1500 1500 1500 1500
Ambient Temperature - Charge
0° to 27° C
32° to 81° F
5° to 45° C
41° to 113° F
5° to 45° C
41° to 113° F
5° to 45° C
41° to 113° F
5° to 45° C
41° to 113° F
5° to 45° C
41° to 113° F
5° to 45° C
41° to 113° F
Ambient Temperature - Discharge
00° to 27° C
32° to 81° F
0° to 50° C
32° to 122° F
0° to 50° C
32° to 122° F
0° to 50° C
32° to 122° F
0° to 50° C
32° to 122° F
0° to 50° C
32° to 122° F
0° to 50° C
32° to 122° F
UL Listing – File Number MH61859 – – – – – – –