25
15: TROUBLESHOOTING
The following matrix will assist you with troubleshooting simple problems that may cause the Deka Ready Power battery to function incorrectly. For
more in depth troubleshooting or repair, refer to the Deka Ready Power Service Manual or contact the local Deka Ready Power Service provider.
PROBLEM
POSSIBLE CAUSE
SERVICE BY DEKA READY POWER
REPRESENTATIVE
Battery won’t power on.
• Battery at a low state of charge (SOC)
• UIM/BDI not connected to battery
• Active fault causing battery shutdown
Connect battery to approved charger.
Inspect UIM/BDI cable connection and
connection to battery.
View UIM/BDI for indication of a fault or use
service tool to connect to battery to ID fault.
Follow service documentation to trouble-
shoot fault.
Battery won’t charge.
• Battery or charger cables damaged
• Both battery cables are not connected to
charger (dual charge cable setup only)
• Charger in a fault state
• Active fault causing battery shutdown
Inspect cables for damage. Replace cables
if necessary.
Connect both battery connectors to charger
(dual cable setup only).
Inspect charger for fault. Follow charger
OEM’s recommended troubleshooting steps.
View UIM/BDI for indication of a fault or use
service tool to connect to battery to ID fault.
Follow service documentation to trouble-
shoot fault.
Battery powers off when
not commanded to.
• Active fault causing battery shutdown
• Battery at a low state of charge (SOC)
• Communication from truck to battery lost
(Integrated setups only)
View UIM/BDI for indication of a fault or use
service tool to connect to battery to ID fault.
Follow service documentation to trouble-
shoot fault.
Connect battery to approved charger.
Inspect communication cables from
truck to battery. Ensure truck is configured
correctly.
UIM/BDI won’t power on.
• UIM/BDI not connected to battery
• UIM/BDI cable damaged
• UIM/BDI damaged
• Active fault causing battery shutdown
Inspect UIM/BDI cable connection and
connection to battery.
Inspect/replace UIM/BDI cables.
View UIM/BDI for indication of a fault or use
service tool to connect to battery to ID fault.
Follow service documentation to trouble-
shoot fault.
UIM data appears to be incorrect.
• Baud rate not set correctly in battery
• UIM cable damaged
• Internal battery fault preventing
communication
Use service tool to inspect/change baud
rate in battery.
Inspect/replace UIM/BDI cables.
View UIM/BDI for indication of a fault or use
service tool to connect to battery to ID fault.
Follow service documentation to trouble-
shoot fault.