Hardware specifications
Note
All ratings assume a fully configured DS60 shelves.
Table 19 Hardware specifications
Specification Description
AC line voltage 200 to 240 Vac ± 10%, single-phase, 47 to 63
Hz
AC line current (operating maximum) 4.9 A max at 200 Vac
Power consumption (operating maximum) 980 VA (931W) max
Power factor 0.95 min at full load, low voltage
Heat dissipation (operating maximum) 3.36 x 10
6
J/hr, (3177 Btu/hr) max
Dimensions (rack mounted)
l
Height: 8.75 in (22.23 cm) 5U (4U plus 1U
cable management tray).
l
Width including rails: 17.50 in (44.45 cm)
l
Depth (chassis only): 34.5 in (87.63 cm)
l
Maximum depth (fully configured): 36.4
in (92.46 cm)
Shelf weight
l
Without FRUs installed: 55.0 lb ( 24.7 kg)
l
With FRUs installed: 225.0 lb (102 kg)
Operating temperature
l
Ambient temperature: 41
o
F to 104
o
F (5
o
C to 40
o
C)
l
Temperature gradient: 18
o
F/hr (10
o
C/hr)
l
Relative humidity extremes: 20% to 80%
noncondensing
Recommended operating relative humidity 40% to 55% noncondensing
Operating elevation -50 to 7500 ft (-16 to 2300 m)
Non-operating (shipping and storage)
temperature
l
Ambient temperature: -40
o
F to 149
o
F
(-40
o
C to 65
o
F)
l
Temperature gradient: 45
o
F/hr
(25
o
C/hr)
l
Relative humidity: 10% to 90%
noncondensing
l
Elevation: -50 to 35,000 ft (-16 to 10,600
m)
Hardware Specifications