Back panel
The back panel has two dual power supplies and two LCCs (Link Controller Cards).
Figure 4 DS60 back panel
Each controller has 4 SAS ports (laid out as 2 pairs). Standard Data Domain systems,
and systems with the licensed HA feature only use ports 0 and 2 on each controller.
Ports 1 and 3 typically have a plastic plug blocking the unused ports to make inserting
a cable into the correct ports easier.
Note
Please refer to Installing the Shelves on page 17 chapter for details about cabling.
The Cabling shelves on page 24 section provides the needed details.
Table 7 Status lights visible from rear of disk enclosure
Light Quantity Color Meaning
Controller
power
1 per controller Green On when the Controller is powered on.
Controller fault 1 per controller Amber On when either the Controller or a SAS
connection is faulty. On during power-on
self test.
Link active 4 per controller Blue On when the host connection is active.
Power supply
input voltage
1 per power
supply
Green Input power green when it is working.
Power supply
fault*
1 per power
supply
Amber
l
On when the power supply is faulty or
is not receiving AC line voltage.
l
Flashing when either a multiple blower
or ambient over temperature condition
has shut off DC power to the system.
The DS60 continues to run with a single power supply and two fans (out of the three
fans).