3-4 Dell PowerEdge 4100/180 and 4100/200 Systems Service Manual
Real-time
clock error
Real-time clock on
system board mal-
functioned.
Defective micro-
processor or system
board.
Keyboard
controller
error
Cable may be loose,
keyboard may be
faulty, or keyboard
controller is defec-
tive.
Defective keyboard,
keyboard cable, or
system board.
EISA con-
figuration
NVRAM bad
EISA jumper may
have been acciden-
tally installed.
Ensure EISA jumper
is removed; then
reboot system and
restore EISA configu-
ration.
EISA con-
figuration
error
EISA configuration
data in NVRAM
does not match the
installed EISA
expansion cards.
Ensure EISA expan-
sion cards are seated
properly; then run
EISA Configuration
Utility.
Invalid CPU
speed
detected -
check
jumpers
Microprocessor
speed jumper plug
may be absent or
installed on wrong
jumper pins.
Check the micro-
processor speed
jumpers.
Resource
conflict
Warning:
IRQ not
initialized
Expansion
ROM not
initialized
BIOS detected a
resource conflict
while configuring
Plug and Play ISA
or PCI expansion
card.
See “Eliminating
Resource Conflicts”
in Chapter 2.
System con-
figuration
data write
error
System board may
be malfunctioning.
Defective system
board.
System mem-
ory size has
changed -
Run Config-
uration
Utility
DIMM was added or
removed. DIMMs
are improperly
seated.
More memory was
added. Make sure
DIMMs are properly
seated; run EISA
Configuration Utility.
Table 3-2. System Error Messages (continued)