DD6800 and DD9300 with HA
DD6800 and DD9300 with HA
Table 42 Primary node cabling instructions
String
(Loop)
I/O - Port Shelf Port Length
a
1 I/O 7 - Port 0 A controller port 0 of shelf V1.1 2M
1 I/O 2 - Port 0 B controller port 0 of the highest number shelf in V1 2M
2 I/O 7 - Port 1 A controller port 0 of shelf V2.1 2M
2 I/O 2 - Port 1 B controller port 0 of the highest number shelf in V2 2M
3 I/O 7 - Port 2 A controller port 0 of shelf V3.1 2M
3 I/O 2 - Port 2 B controller port 0 of the highest number shelf in V3 2M
4 I/O 7 - Port 3
A controller HOST port of the SSD shelf
2M
4 I/O 2 - Port 3
B controller HOST port of the SSD shelf
2M
a.
Cable lengths shown are designed for Data Domain racks. Longer cables (up to 5M) can be
used.
Table 43 Standby node cabling instructions
String
(Loop)
I/O - Port Shelf Port Length
a
1 I/O 7 - Port 0 B controller port 2 of shelf V1.1 2M
1 I/O 2 - Port 0 A controller port 2 of the highest number shelf in V1 2M
2 I/O 7 - Port 1 B controller port 2 of shelf V2.1 2M
2 I/O 2 - Port 1 A controller port 2 of the highest number shelf in V2 2M
3 I/O 7 - Port 2 B controller port 2 of shelf V3.1 2M
3 I/O 2 - Port 2 A controller port 2 of the highest number shelf in V3 2M
4 I/O 7 - Port 3
A controller EXPANSION port of the SSD shelf
2M
4 I/O 2 - Port 3
B controller EXPANSION port of the SSD shelf
2M
a.
Cable lengths shown are designed for Data Domain racks. Longer cables (up to 5M) can be
used.
Connect Cables and Power on