28 Cabling Your Cluster Hardware
Figure 2-9. Cabling a SAN-Attached Cluster to an AX4-5F Storage System
Cabling a SAN-Attached Cluster to an AX4-5FX Storage System
1
Connect cluster node 1 to the SAN.
a
Connect a cable from HBA port 0 to Fibre Channel switch 0 (sw0).
b
Connect a cable from HBA port 1 to Fibre Channel switch 1 (sw1).
2
Repeat step 1 for each cluster node.
3
Connect the storage system to the SAN.
a
Connect a cable from Fibre Channel switch 0 (sw0) to SP-A Fibre port
0(First fibre port).
b
Connect a cable from Fibre Channel switch 0 (sw0) to SP-A Fibre port
1(Second fibre port).
c
Connect a cable from Fibre Channel switch 0 (sw0) to SP-B Fibre port
2(Third fibre port).
A
B
A
B
0Fibre 1Fibre 0Fibre 1Fibre
sw0
sw1
cluster node 2
cluster node 1
AX4-5F storage system
0
1
0
1
HBA ports (2)
HBA ports (2)
SP-A
SP-B