52 EMC VNXe3100 Hardware Information Guide
Overview
Specifications
Table 27 lists the VNXe3100 platform physical specifications, operating environment, and
power requirements.
Table 27 VNXe3100 platform specifications
Parameter Characteristics
Dimensions (approximate)
Height 28 in. (71.12 cm) or 16 NEMA units (U) total; one disk
processor enclosure (DPE, 2U) and seven disk-array enclosures
(2U, 12 [3.5-inch] DAE)
Width 17.5 in. (44.5 cm); mounting bars fit standard 19-inch NEMA
cabinets
Depth Chassis to rear: 19.5 in. (49.53 cm)
Weight 424.5 lb (192.55 kg) total; one DPE and seven 2U, 12 (3.5-inch)
DAEs
Operating environment
Temperature 50-104° F (10-40° C)
Temperature gradient 18° F/hr (10° C/hr)
Relative humidity 20% to 80% (non-condensing)
Altitude 8,000 ft (2,438 m) @ 104° F (40° C) max.
10,000 ft (3,048 m) @ 98.6° F (37° C) max.
AC power and dissipation
AC line voltage 100 to 240 VAC (47-63 Hz), single phase
AC line current 4.0 A max at 100 VAC, 2.0 A max at 200 VAC
1
2.5 A max at 100 VAC, 1.3 A max at 200 VAC
2
Power consumption 395 VA (380 W) max
a
250 VA (240 W) max
b
Power factor 0.98 min at full load, low voltage
Heat dissipation 1.37 x 10
6
J/hr, (1,300 Btu/hr) max
a
8.46 x 10
5
J/hr, (800 Btu/hr) max
b
AC protection 15 A fuse on each power supply, both phases
AC inlet type (receptacle) IEC320-C14 appliance coupler (per power supply)
Ride-through 30 ms minimum at full load
Current sharing ± 15% of full load, between power supplies