Table 17 Management network cabling (continued)
Customer Provided Management Switch
Source Destination
Node 17 BMC (iDRAC) Management Switch Port 29
Node 17 NIC 1 Management Switch Port 31
Data Network Switch A <...> Port Management Switch Port 45
Data Network Switch B <...> Port Management Switch Port 46
Data Network Switch A Mgmt Port Management Switch Port 47
Data Network Switch B Mgmt Port Management Switch Port 48
Management Server NIC 1 Management Switch Port 38
Link to Core Switch or 2nd Rack Management Switch Management Switch Port 52
Data network A wiring for R740XD servers
Use the following figure and table to connect the data network A cables.
Note: In this example, data switch ports have been intentionally left empty. These
empty ports can be used for other user-allocated purposes. If no other use is
required for the empty ports, nodes may be connected to the data switches
without leaving empty ports. However, ensure that on each node, each NIC is
connected to a different data switch (either Data Switch A or Data Switch B), in
order to prevent a single point of failure in case a switch fails.
Wiring Diagrams for a R740XD Configuration
74 Dell EMC VxFlex Ready Node Server Installation Guide