Dell - Internal Use - Confidential
28 Room for text | Dell Inc., 2014
Length (inches /
centimeters)
Height (inches /
centimeters)
Length (inches /
centimeters)
System Level Environmental and Operating Conditions
5° to 35° C (41° to 95° F)
-40° to 65° C (-40° to 149° F)
-40° to 65° C (-40° to 149°F)
20% to 80% (non-condensing)
20% to 80% (non-
condensing)
0.26Grms random at 5 to 350 Hz
0.26Grms random at 5 to 350
Hz
2.2 Grms random at 5 to 500 Hz
1.37Grms random at 5 to 500
Hz
Bottom half-sine pulse with a change in
velocity
of 50.8 cm/sec (20 inches/sec)
Bottom half-sine pulse with a
change in velocity of 50.8
cm/sec (20 inches/sec)
105G half-sine pulse with a change in
velocity of
133cm/sec (52.5inches/sec)
105G half-sine pulse with a
change in velocity of
133cm/sec (52.5inches/sec)
–15.2 to 3048 m (–50 to 10,000 ft)
–15.2 to 3048 m (–50 to
10,000 ft)
–15.2 to 10,668 m (–50 to 35,000 ft)
–15.2 to 10,668 m (–50 to
35,000 ft)
POWER
NOTE: These form factors utilize a more efficient Active Power Factor Correction (APFC) power
supply. Dell recommends only Universal Power Supplies (UPS) based on Sine Wave output for APFC
PSUs, not an approximation of a Sine Wave, Square Wave, or quasi-Square Wave. If you have
questions, please contact the manufacturer to confirm the output type.