2. Upgrade CPLD from console.
console#dev cpldUpdate
Device #1 Silicon ID is ALTERA04(01)
erasing MAXII device(s)...
erasing MAXII UFM block...
erasing MAXII CFM block...
programming CFM block...
programming UFM block...
verifying CFM block...
verifying UFM block...
DONE
CPLD update exited with a return code of 0
error_address 180300310, exit_code 0, format_version 2
value = -1 = 0xffffffff
3. Power cycle the switch - Hard reboot required. Power disconnected for 10 seconds. Each unit of the
stack will require a hard reboot
.
4. Repeat Steps 1 through 3 on each member unit in the Stack of PC8024/PC8024F switches. The above
CPLD update instructions are allowed to run from serial console prompt (for example.
(Unit 2 -
CLI unavailable - please connect to master on Unit 1)>devshell cpldTest)
of all members in
the stack even if it’s not the Master switch.
5. Verify the updated CPLD version after switch power cycle.
console#dev cpldTest
Board Type : Campbell 24F
Board Version : 2
CPLD Revision : 6 (0x6)
RPS2 Present
RPS2 Status : Working
RPS2 Temperature : Normal
RPS2 Fan Status : Working
RPS1 Present
RPS1 Status : Working
RPS1 Temperature : Normal
RPS1 Fan Status : Working
Port SFP Status Link Status Tx Power
---- ---------- ----------- --------
1 Present Up Enabled
2 Present Up Enabled
3 Not Present Down Disabled
4 Not Present Down Disabled
5 Not Present Down Disabled
6 Not Present Down Disabled
7 Not Present Down Disabled
8 Not Present Down Disabled
9 Present Up Enabled
10 Present Up Enabled
11 Not Present Down Disabled
12 Not Present Down Disabled
13 Not Present Down Disabled
14 Not Present Down Disabled
15 Not Present Down Disabled
16 Not Present Down Disabled
17 Not Present Down Enabled
18 Not Present Down Enabled
19 Not Present Down Disabled
20 Not Present Down Disabled
21 Not Present Down Disabled
22 Not Present Down Disabled
23 Not Present Down Disabled
24 Not Present Down Disabled
Fan1 Status : Working
Fan2 Status : Working
Fan3 Status : Working
value = 36 = 0x24

Other manuals for Dell PowerConnect 7024

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect 7024 and is the answer not in the manual?

Dell PowerConnect 7024 Specifications

General IconGeneral
BrandDell
ModelPowerConnect 7024
CategorySwitch
LanguageEnglish

Related product manuals