PowerConnect 8024/8024F Release Notes
Page 8 System Firmware Version 3.1.4.16
Description User Impact Resolution
Switch throws errors of level
info/debug when clearing PFC
interface counters or checking PFC
interface counters.
Error messages are displayed on the
console and the counters not
incremented properly due to
misintepreted failure conditions.
Now counters are properly handled
based on the applicable registers.
Switch uploads startup-config when
tried uploading running-config.
Running-config cannot be uploaded
from web.
Corrected algorithm to determine
proper file type to upload.
PFC counters on LAG interface are
not incrementing.
Error messages are displayed on the
console and the counters not
incremented properly due to
misinterpreted failure conditions.
Now counters are properly handled
based on the applicable registers.
Summer Time enabled does not
reflect correctly in the output of 'show
running-config' and 'show clock detail'.
When summer time is configured, the
time reported is incorrect.
Updated the algorithm to correctly
calculate the summer-time period.
Recurring Summer Time is getting
configured for max offset value even
though offset is not configured.
When summer time is configured, the
time reported is incorrect.
Updated the algorithm to correctly
calculate the summer-time period.
Location information is not found in
CLI / Web when Recurring Summer
Time is configured.
show commands do not reflect the
correct status, when summer-time for
EU or USA is configured.
Detect when the configuration
matches those modes to allow user
to identify what mode was selected.
Summer Time does not work when
date falls under configured window.
When summer time is configured, the
time reported is incorrect.
Updated the algorithm to correctly
calculate the summer-time period.
Web does not show starting / ending
month & year for non-recurring
summer time configuration.
The Start Month and Year, End Month
and Year fields were missing in the
Clock Detail Web page.
Added missing fields to the web
page
IGMP Queriers are sent out from the
switch after the pre-configured 60
secs interval
Partner would receive IGMP querier
packets later than the expected time,
even though the delay is neglected.
Updated cpu utilization mechanism
along with using accurate values for
system clock.
Summer Time offset range is not
correct.
User is allowed to configure out of
range values from the web page.
Corrected help string along with field
validations.
deleting key from Radius
configuration mode.
Upgrade PHY firmware to version
1.4.1.0
10G copper ports may take 2-5
minutes to link-up.
Switches automatically upgrade the
PHY firmware that corrects link up
time.
Switch is accepting any letter other
than "y" to generate SSH key.
Switch generates SSH key on
entering anything other than 'n' letter,
even though help is saying that it
allows only 'y' or 'n'.
Modified validation to not allow
anything other than 'y'/'n'
No button is selected by default in the
copy file web page
No button is selected by default in the
copy file web page
Modified web page to have a default
selection.