PowerConnect 8024/8024F Release Notes
Page 18 System Firmware Version 3.1.4.16
Cable Diagnostics
Description User Impact
Time is reported as UTC and not
local time in log files and CLI for
copper ports.
The times are not adjusted for the local time zone.
Issues with show fiber-ports optical-
transceiver output.
The port is enabled when the fiber diagnostics are run. Because of this,
the user sees the same diagnostics for both port up and down. There is
also an invalid value that shows in power out.
Management ACL
Description User Impact
Management ACL is not working for
Out-Of-Band interface
Management ACLs are not implemented on the Out-Of-Band interface.
SNTP
Description User Impact
Too many SNTP messages in log file. The log can fill up with informational message of SNTP: system clock
synchronized. Change Log message from notice level to NTP debug
level in order to avoid the additional messages.
User Manager
Description User Impact
A user that configures a User Level
15 and disables the RADIUS
authentication server may not be able
to login.
When the radius server does not exist and the authentication fails, the
next authentication method is not getting invoked.
End of Release Notes