568 PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Managing ACL comment text
16
The <comment-text> can be up to 128 characters in length.  The comment must be entered 
separately from the actual ACL entry; that is, you cannot enter the ACL entry and the ACL comment 
with the same access-list or ip access-list command.  Also, in order for the remark to be displayed 
correctly in the output of show commands, the comment must be entered immediately before the 
ACL entry it describes.  Note that an ACL comment is tied to the ACL entry immediately following the 
comment.  Therefore, if the ACL entry is removed, the ACL comment is also removed.
The standard | extended parameter indicates the ACL type.
Adding a comment to an entry in a named ACL
To add comments to entries in a named ACL, enter commands such as the following.
Syntax: [no] access-list  standard | extended <ACL-name> 
Syntax: remark  <comment-text>
The standard | extended parameter indicates the ACL type.
For <ACL-name>, enter the name of the ACL.
The <comment-text> can be up to 128 characters in length.  The comment must be entered 
separately from the actual ACL entry; that is, you cannot enter the ACL entry and the ACL comment 
with the same ip access-list command.  Also, in order for the remark to be displayed correctly in the 
output of show commands, the comment must be entered immediately before the ACL entry it 
describes.   Note that an ACL comment is tied to the ACL entry immediately following the comment.  
Therefore, if the ACL entry is removed, the ACL comment is also removed.
Deleting a comment from an ACL entry
To delete a comment from an ACL entry, enter commands such as the following.
PowerConnect(config)#ip access-list standard 99
PowerConnect(config)#no remark The following line permits TCP packets
Syntax: no remark <comment-text>
Viewing comments in an ACL
You can use the following commands to display comments for ACL entries:
• show running-config 
• show access-list 
• show ip access-list 
The following shows the comment text for a numbered ACL, ACL 100, in a show running-config 
display.
PowerConnect(config)#ip access-list extended TCP/UDP
PowerConnect(config-ext-nACL)#remark The following line permits TCP packets 
PowerConnect(config-ext-nACL)#permit tcp 192.168.4.40/24 2.2.2.2/24
PowerConnect(config-ext-nACL)#remark The following permits UDP packets
PowerConnect(config-ext-nACL)#permit udp 192.168.2.52/24 2.2.2.2/24
PowerConnect(config-ext-nACL)#deny ip any any