10 Tower-to-Rack Conversion Guide
Figure 1-2. Removing the Tower Bezel
Preparing the System for Conversion
1 Turn off the system and attached peripherals, and disconnect the system from the electrical outlet
and peripherals.
2
Note the order of the hard drives in your system and remove all hard drive carriers and drive blanks
from the drive bays.
3
If present, remove the filler panels from the peripheral bay.
NOTE: It is not necessary to remove any devices installed in the peripheral bay.
4
If present, unlock and remove the Kensington cable lock on the back of the system chassis.
CAUTION: The system may weigh up to 45 kilograms (100 pounds) when fully loaded. To prevent personal injury,
do not attempt to move the system by yourself.
5
Place the system on its side on a flat, level work surface and orient the system so that the feet hang over
the edge of the table.
1 bezel 2 keylock 3 release latch
3
1
2
book.book Page 10 Friday, May 26, 2006 3:03 PM