Tower-to-Rack Conversion Guide 19
Installing the Optional 1x2 Flex Bay Bracket
NOTE: The rack front panel is keyed so that the 1x2 flex bay bracket installs in the opposite orientation as the
tower front panel.
1
Insert the 1x2 flex bay bracket three-quarters of the way into the peripheral bay.
2
Reconnect the power cable to the flex bay backplane. See
Figure 1-8
.
3
Reconnect the SAS cables to the connectors on the flex bay backplane. See Figure 1-8.
4
Push the flex bay bracket the rest of the way into the peripheral bay until the spring latch on top of the
peripheral bay engages.
Figure 1-8. Installing the Optional 1x2 Flex Bay Bracket
1 peripheral bay spring latch 2 SAS cable (SAS_B_IN
connector)
3 SAS cable (SAS_B_OUT
connector)
4 power connector 5 1x2 flex bay drive bracket 6 slot key
7 flex bay
5
6
7
1
2
3
4