3-6 Dell PowerEdge 4300 Systems User’s Guide
location on the backplane board for the SCSI ID of each drive location. The default
for Boot Target ID is 0.
Boot LUN Number — If your boot device has multiple logical unit numbers
(LUNs) and Multiple LUN Support is enabled (see “Advanced Host Adapter Set-
tings” found later in this section), this option allows you to specify a particular
LUN from which to boot on your boot device. The default is 0.
6&6,'HYLFH &RQILJXUDWLRQ6HWWLQJV
SCSI Device/Configuration Settings allows you to configure certain parameters for
each device on the SCSI bus. To configure a specific device, you must know the SCSI
ID assigned to that device. If you are not sure of the SCSI ID, see “SCSI Disk Utilities”
found earlier in this section.
Initiate Sync Negotiation — This option determines whether the host adapter
initiates synchronous data transfer negotiation (sync negotiation) between itself
and the device. The default is Yes.
Sync negotiation is a SCSI feature that allows the host adapter and its attached
SCSI devices to transfer data in synchronous mode. Synchronous data transfer is
faster than asynchronous data transfer.
The host adapter always responds to sync negotiation if the SCSI device initiates
it. If neither the host adapter nor the SCSI device initiates sync negotiation, data
is transferred asynchronously.
Normally, you should leave Initiate Sync Negotiation enabled (a setting of Yes),
because most SCSI devices support sync negotiation and because it allows for
faster data transfer.
NOTE: Some older SCSI-1 devices do not support sync negotiation. This may
cause your computer to operate erratically or hang if
Initiate Sync Negotiation
is set to
Yes
. Set
Initiate Sync Negotiation
to
No
for these devices.
Maximum Sync Transfer Rate (MB/sec) — This option sets the maximum syn-
chronous data transfer rate that the host adapter supports. The host adapter
supports rates up to 80 megabytes per second (MB/sec). The default for the
Adaptec AIC-7860 host adapter is 20; the default for the AIC-7890 and 2940U2W
host adapters is 80.
If the host adapter is set so that it does not negotiate for synchronous data trans-
fer, the maximum synchronous transfer rate is the maximum rate that the host
adapter accepts from the device during negotiation. (This is standard SCSI
protocol.)
Enable Disconnection — This option (sometimes called
disconnect/reconnect
)
determines whether the host adapter allows the SCSI device to disconnect from
the SCSI bus. Enabling disconnection allows the host adapter to perform other
operations on the SCSI bus while the SCSI device is temporarily disconnected.
The default is Yes.
Leave Enable Disconnection set to Ye s if two or more SCSI devices are con-
nected to the host adapter. This optimizes SCSI bus performance. If only one
33255bk0.book Page 6 Tuesday, August 25, 1998 8:46 AM