EasyManua.ls Logo

Dell PowerEdge H730P - Virtual Disk Management

Dell PowerEdge H730P
101 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Description
Read Policy Read-Ahead enables the read-ahead feature for the virtual disk. You can set
the parameter to Read-Ahead, No-Read-Ahead, or Adaptive-Read-Ahead.
The default is Adaptive-Read-Ahead.
Read-Ahead specifies that the controller uses Read-Ahead for the current
virtual disk. Read-Ahead capability allows the controller to read sequentially
ahead of requested data and store the additional data in the cache memory,
anticipating that the data is required soon.
No-Read-Ahead specifies that the controller does not use read ahead for the
current virtual disk.
Adaptive-Read-Ahead specifies that the controller begins using Read-Ahead
if the two most recent disk accesses occurred in sequential sectors. If all read
requests are random, the algorithm reverts to No-Read-Ahead; however, all
requests are still evaluated for possible sequential operation.
Virtual Disk Management
Creating Virtual Disks
NOTE: Combining SAS and SATA disk drives within a virtual disk is not supported. Also, combining
disk drives and SSDs within a virtual disk is not supported.
NOTE: To create secured virtual disks, see Security Key And RAID Management.
Perform the following steps to create a virtual disk:
1. During host system bootup, press <Ctrl><R> after the BIOS screen is displayed.
The Virtual Disk Management screen is displayed. If there is more than one controller, the main
menu screen is displayed. Select a controller, and press <Enter>. The Virtual Disk Management
screen is displayed for the selected controller.
2. Use the arrow keys to highlight PERC H730P Adapter or Disk Group #.
3. Press <F2>.
A list of available actions is displayed.
4. Select Create New VD and press <Enter>.
The Create New VD screen is displayed. The cursor is on the RAID Level option. When adding a
virtual disk to a Disk Group, the Add VD in Disk Group screen is displayed. Skip to step 11 to change
the basic settings of the virtual disk.
5. Press <Enter> to display the possible RAID levels.
6. Press the down-arrow key to select a RAID level and press <Enter>.
7. When creating a spanned virtual disk (RAID 50 or 60), enter the number of physical disks per span in
the PD per Span field and press <Enter>.
8. Press <Tab> to move the cursor to the list of physical disks.
9. Use the arrow key to highlight a physical disk and press the spacebar, <Alt> , or <Enter> to select the
disk.
10. Select additional disks, if required.
11. Press <Tab> to move the cursor to the Basic Settings box.
44