PowerEdge M1000e Technical Guide 48
Wake on LAN (WOL) is enabled after a power down and power up of the enclosure. FlexAddress on
Ethernet devices is programmed by the module server BIOS. In order for the blade BIOS to program
the address, it needs to be operational which requires the blade to be powered up. Once the power-
down and power-up sequence completes, the FlexAddress feature is available for Wake-On-LAN
(WOL) function.
Following are the four steps required in order to implement FlexAddress on an M1000e:
A Chassis Management Controller (CMC) receives a FlexAddress feature card provisioned with
a unique pool of: 208 MACs and 64 WWNs.
Figure 38. FlexAddress SD Card
The FlexAddress card is inserted at factory or to an already installed chassis in an customer
location (note: to Enable FlexAddress on an existing chassis, blade BIOS, iDRAC firmware, HBA
and Ethernet controller firmware, and CMC firmware must be updated to the latest versions)
Figure 39. SD Slot on bottom of CMC
Select the slots and fabrics you want FlexAddress enabled on (see figure below). note blades
must be powered off and have the latest firmware in order for FlexAddress MAC/WWNs to be
deployed to them.