Error Code Message Information
SWC4004
Message A firmware or software incompatibility detected between iDRAC in
slot <
number
> and CMC.
Details FlexAddress is not implemented in one of the versions of firmware.
Action Check the firmware versions of iDRAC and CMC. Update with the
latest version.
SWC4006
Message A firmware or software incompatibility detected between system
BIOS in slot <
number
> and CMC.
Details FlexAddress is not implemented in one of the versions of firmware.
Action Check the firmware versions of BIOS and CMC. Update with the latest
version.
SWC4008
Message A firmware or software incompatibility detected between CMC 1 and
CMC 2.
Details FlexAddress is not implemented in one of the versions of firmware.
Please update the firmware.
Action Check firmware versions. Update CMC 1 and CMC 2 firmware to
match.
SWC5001
Message <
name
> upgrade failed.
Action Reboot the system and attempt the upgrade again.
TMP0100
Message The system board <
name
> temperature is less than the lower
warning threshold.
LCD Message System board <
name
> temperature is outside of range.
Details Ambient air temperature is too cool.
Action Check the system operating environment.
TMP0101
Message The system board <
name
> temperature is less than the lower critical
threshold.
LCD Message System board <
name
> temperature is outside of range.
Details Ambient air temperature is too cool.
Action Check the system operating environment.
TMP0102
Message The system board <
name
> temperature is greater than the upper
warning threshold