Error Code Message Information
Details System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Remove the processor module. Inspect processor socket for
bent pins.
3. If the issue persists, see Getting Help.
VLT0102
Message Processor module <
name
> voltage is greater than the upper warning
threshold.
LCD Message Processor module <
name
> voltage is outside of range.
Details System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Remove the processor module. Inspect processor socket for
bent pins.
3. If the issue persists, see Getting Help.
VLT0103
Message Processor module <
name
> voltage is greater than the upper critical
threshold.
LCD Message Processor module <
name
> voltage is outside of range.
Details System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Remove the processor module. Inspect processor socket for
bent pins.
3. If the issue persists, see Getting Help.
VLT0104
Message Processor module <
name
> voltage is outside of the allowable range.
LCD Message Processor module <
name
> voltage is outside of range.
127