EasyManua.ls Logo

Dell PowerEdge M520 - Page 84

Dell PowerEdge M520
139 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Error Code Message Information
CPU0704
Message CPU <
number
> machine check error detected.
LCD Message CPU <
number
> machine check error detected. Power cycle system.
Details System event log and operating system logs may indicate that the
exception is external to the processor.
Action
1. Check system and operating system logs for exceptions. If no
exceptions are found, continue.
2. Turn system off and remove input power for one minute.
3. Ensure the processor is seated correctly.
4. Reapply input power and turn system on.
5. If the issue persists, see Getting Help.
CPU0801
Message CPU <
number
> voltage regulator module failed.
LCD Message CPU <
number
> voltage regulator module failed. Re-seat module.
Details System performance may be degraded or the system may fail to
operate.
Action
1. Turn system off and remove input power for one minute.
2. Reapply input power and turn system on.
3. Ensure the processor is seated correctly.
4. If the issue persists, see Getting Help.
CPU0802
Message A predictive failure detected on CPU <
number
> voltage regulator
module.
Details System performance may be degraded or the system may fail to
operate.
Action
1. Turn system off and remove input power for one minute.
2. Reapply input power and turn system on.
3. Ensure the processor is seated correctly.
4. If the issue persists, see Getting Help.
CPU0803
Message The power input for CPU <
number
> voltage regulator module is lost.
LCD Message Lost power input for CPU <
number
>voltage regulator module. Re-seat
module.
Details System performance may be degraded or the system may fail to
operate.
84