26 About Your System
E141C CPU Mismatch Processors are in a
configuration unsupported
by Dell.
Ensure that your
processors match and
conform to the type
described in the
Microprocessor Technical
Specifications outlined in
your system’s Getting
Started Guide.
E141F CPU Protocol The system BIOS has
reported a processor
protocol error.
See "Getting Help" on
page 167.
E1420 CPU Bus PERR The system BIOS has
reported a processor bus
parity error.
See "Getting Help" on
page 167.
E1421 CPU Init The system BIOS has
reported a processor
initialization error.
See "Getting Help" on
page 167.
E1422 CPU Machine
Chk
The system BIOS has
reported a machine check
error.
See "Getting Help" on
page 167.
E1610 PS # Missing No power is available from
the specified power supply;
specified power supply is
improperly installed or
faulty.
See "Troubleshooting
Power Supplies" on
page 135.
E1614 PS # Status No power is available from
the specified power supply;
specified power supply is
improperly installed or
faulty.
See "Troubleshooting
Power Supplies" on
page 135.
E1618 PS #
Predictive
Power supply voltage is out
of acceptable range;
specified power supply is
improperly installed or
faulty.
See "Troubleshooting
Power Supplies" on
page 135.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions