No. Task Reference Avaya recommendation
• R610 SRVR RAID
BATTERY
HOM: RAID Battery Keyboard, monitor, and
mouse required for advanced
troubleshooting.
3 If the part is defective,
see Replacing internal
server components.
Replacing external components
Use the checklist below to replace any of the following external server components:
Part number Description Hot-swappable?
700501316 R610 SRVR 146GB 10K SAS 2.5” HDD Y
700501317 R610 SRVR 146GB 15K SAS 2.5” HDD Y
700501315 R610 SRVR 300GB 10K SAS 2.5” HDD Y
700501421 R610 SRVR 600GB 10K SAS 2.5" HDD Y
700501183 R610 SRVR AC PWR SUP 502W ES Y, if redundant
700501311 R610 SRVR AC PWR SUP 717W Y, if redundant
Note:
Hard disk drives and redundant power supplies are hot-swappable; you do not have to power
down the server. Replacing a power supply usually does not require removing the server from
the rack unless cables or other obstructions prevent removing and replacing the power supply.
No. Task Reference Avaya recommendation
1 Power down server (if
necessary)
Determine whether the
replaceable component is
hot-swappable.
2 Slide the server out of the
rack (if necessary)
RI-SR
CMAI: Moving the CMA Away
from the CMA Tray
Ensure that the Cable
Management Arm (if
present) moves freely out of
the way of rear panel
components.
3 Replace the component:
• R610 SRVR 146GB 10K
SAS 2.5” HDD
• R610 SRVR 146GB 15K
SAS 2.5” HDD
HOM: Hard drives
Table continues…
Replacing external components
November 2010 Maintaining and Troubleshooting the Dell
™
PowerEdge
™
R610 Server 13
Comments on this document? infodev@avaya.com