No. Task Reference Avaya
recommendation
2 Observe safety warnings HOM: Safety First—For You
and Your System
3 Power down server
4 Slide the server out of the
rack
RI-SR
5 Remove the cover HOM: Opening and Closing
the System
Electrostatic alert:
Ensure that you are
properly grounded
before handling
internal
components.
6 Replace the component:
• R610 SRVR DUAL
PORT 1GB NIC
HOM: Expansion Cards Mark any external
cables connected to the
NIC and reconnect to
the same ports after the
NIC is replaced.
• R610 SRVR DVD-RW
DRIVE W/ BRKT
HOM: Optical Drive In the Removing an
Optical Drive section
perform steps 2–5 only.
In the Installing an
Optical Drive section
perform steps 2–6, 8,
and 10 only.
• R610 SRVR FAN FRU HOM: Cooling Fans
Caution:
Do not attempt to
hot-swap a fan.
• R610 SRVR 2GB
MEMORY DIMM
• R610 SRVR 4GB
MEMORY DIMM
HOM: System Memory
Consult server cover
label for memory
placement.
Consult application/
solution documentation
for specific procedures.
• R610 SRVR RAID
BATTERY
HOM: RAID Battery Remove the battery
from the cable.
Do not replace the
battery cable unless it is
defective.
Table continues…
Replacing internal components
November 2010 Maintaining and Troubleshooting the Dell
™
PowerEdge
™
R610 Server 15
Comments on this document? infodev@avaya.com