Code Text Causes Corrective action
E1116 Temp Memory Memory has exceeded
acceptable temperature and
has been disabled to prevent
damage to the components.
Check room temperature and external
air flow. If both are within acceptable
limits, then escalate for possible
server replacement.
E12nn xx PwrGd Specified voltage regulator
has failed.
Escalate for possible server
replacement.
E1210 CMOS Batt CMOS battery is missing, or
the voltage is out of
acceptable range.
Shut down server for 1 hour and
disconnect the power supply. If
problem continues, escalate for
possible server replacement.
E1211 ROMB Batt RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Check room temperature and external
air flow. If both are within acceptable
limits, then escalate for possible
server replacement.
E1216 3.3V Regulator
failure
3.3V voltage regulator has
failed.
See HOM: Troubleshooting
Expansion Cards. Turn off the system
and attached peripherals. Power
down system and unplug power cord.
Open system and ensure that
expansion card riser and expansion
card are firmly seated. Close system,
power up. If trouble persists, replace
card.
E1229 CPU # VCORE Processor # VCORE voltage
regulator has failed.
Escalate for possible server
replacement.
E122A CPU # VTT
Regulator failure
Specified processor VTT
voltage regulator has failed
Replace the server.
E122C CPU Power Fault A power fault was detected
when powering up the
processor(s).
Remove AC power to the system for
10 seconds and restart the system.
E122D Memory Regulator #
Failed
One of the memory
regulators has failed.
Reseat the memory modules.
E122E On-board regulator
failed.
One of the on-board voltage
regulators failed.
Remove AC power to the system for
10 seconds and restart the system.
E1310 RPM Fan ## RPM of specified cooling fan
is out of acceptable operating
range.
Check room temperature and external
air flow. If both are within acceptable
limits, then escalate for possible
server replacement.
E1311 RPM Fan Mod #x RPM of fan x in the # module
is out of acceptable operating
range.
Check room temperature and external
air flow. If both are within acceptable
limits, then escalate for possible
server replacement.
E1313 Fan Redundancy The system is no longer fan-
redundant. Another fan
Check room temperature and external
air flow. If both are within acceptable
Table continues…