Loading...
Error Code Message Information
Action Check the memory configuration. Re-seat the memory modules. If the issue persists,
see Getting Help.
MEM0701
Message Correctable memory error rate exceeded for <
location
>.
Details The memory may not be operational. This an early indicator of a possible future
uncorrectable error.
Action Re-seat the memory modules. If the issue persists, see
Getting Help.
MEM0702
Message Correctable memory error rate exceeded for <
location
>.
LCD Message Correctable memory error rate exceeded for <
location
>. Re-seat memory.
Details The memory may not be operational. This an early indicator of a possible future
uncorrectable error.
Action Re-seat the memory modules. If the issue persists, see
Getting Help.
MEM1205
Message Memory mirror redundancy is lost. Check memory device at location(s) <
location
>.
LCD Message Memory mirror lost on <
location
>. Power cycle system.
Details The memory may not be seated correctly, misconfigured, or has failed.
Action Check the memory configuration. Re-seat the memory modules. If the issue persists,
see
Getting Help.
MEM1208
Message Memory spare redundancy is lost. Check memory device at location <
location
>.
LCD Message Memory spare lost on <
location
>. Power cycle system.
Details Memory sparing is no longer available.
Action Re-seat the memory modules. If the issue persists, see
Getting Help.
MEM8000
Message Correctable memory error logging disabled for a memory device at location <
location
>.
LCD Message SBE log disabled on <
location
>. Re-seat memory.
Details Errors are being corrected but no longer logged.
Action
Review system logs for memory exceptions. Reinstall memory at location <
location
>.
PCI1302
Message A bus time-out was detected on a component at bus <
bus
> device<
device
> function <
func
>.
Details System performance may be degraded. The device has failed to respond to a transaction.
Action Cycle input power, update component drivers, if device is removable, reinstall the device.
PCI1304
Message An I/O channel check error was detected.
LCD Message I/O channel check error detected. Power cycle system.