Table 20. M.2 Support Thermal Limitation for XR4000r chassis (RAF Configurations)
M.2
Type
Riser Module Mancini Module AIC Card M.2 Module (Witness
Sled)
Edge 2
(Max
55°C)
Edge 1
(Max
50°C)
ASHRAE
A4 (Max
45°C)
Edge 2
(Max
55°C)
Edge 1
(Max
50°C)
ASHRA
E A4
(Max
45°C)
Edge 2
(Max
55°C)
Edge 1
(Max
50°C)
ASHRA
E A4
(Max
45°C)
Edge 2
(Max
55°C)
Edge 1
(Max
50°C)
ASHRA
E A4
(Max
45°C)
Micro
n
480G
B
Yes Yes Yes Yes Yes Yes Yes Yes Yes No No No
Micro
n
800G
B
Yes Yes Yes Yes Yes Yes Yes Yes Yes No No No
Micro
n
960G
B
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Micro
n
1.92T
B
Throttli
ng
Active
Yes Yes No No No Yes Yes Yes No No No
Micro
n
3.84T
B
Throttli
ng
Active
Yes Yes No No No Yes Yes Yes No No No
Hynix
480G
B
Yes Yes Yes Yes Yes Yes Yes Yes Yes No No No
Hynix
800G
B
Yes Yes Yes Yes Yes Yes Yes Yes Yes No No No
Hynix
960G
B
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Hynix
1.92T
B
Yes Yes Yes No No No Yes Yes Yes No No No
Hynix
3.84B
T
Yes Yes Yes No No No Yes Yes Yes No No No
Table 21. XR4000w Processor Support Thermal Limitation for XR4000r chassis (RAF Configurations)
CPU Type HSK type Fan type
RAF Configurations
Edge 2 (Max
55°C)
Edge 1 (Max
50°C)
ASHRAE A4 (Max
45°C)
Intel Atom C3508, 4 cores, 11.5W
Aluminum
extrusion
Fan Yes Yes Yes