# esxcli nmp satp addrule –s VMW_SATP_ALUA –V DELL –M
array_PID
-c
tpgs_off
Where,
array_PID
is your storage array model/product ID. To select the appropriate
array_PID
for your storage
array, see the following table.
Table 8. Storage Arrays and Model/Product IDs (
array_PID
)
Storage Array
array_PID
MD3260
MD32xx
MD3260i
MD32xxi
MD3660i
MD36xxi
MD3660f
MD36xxf
2. Reboot your ESX-based host server.
Manually Adding SATP Rule In ESX/ESXi 5.0
To manually add the SATP rule in ESX/ESXi 5.0:
1. Run the following command: # esxcli storage nmp satp rule add –s VMW_SATP_ALUA –V
DELL –M
array_PID
-c tpgs_on
Where,
array_PID
is your storage array model/product ID. To select the appropriate
array_PID
for your storage
array, see the table Storage Arrays and Model/Product IDs (
array_PID
) in Manually Adding SATP Rule In ESX 4.1
(Update 1 And Update 2).
2. Reboot your ESX-based host server.
Verifying ALUA On VMware ESX/ESXi
To verify that the SATP claim rule you set is added in VMware ESX/ESXi:
Run the following command for ESX 4.1 (all versions):
# esxcli nmp satp listrules -s VMW_SATP_LSI
Verify that the claim rule for the VID/PID = Dell
/array_PID
shows Claim Options with the tpgs_off
flag specified.
Run the following command for ESX/ESXi 5.0:
# esxcli storage nmp satp rule list –s VMW_SATP_ALUA
Verify that the claim rule for VMW_SATP_ALUA with the VID/PID = Dell
/array_PID
shows the tpgs_on
flag specified.
Verifying If Host Server Is Using ALUA For MD Storage Array
To confirm that the host server is using the ALUA plugin:
For ESX 4.1, run the following command: #esxcli nmp device list
For ESX/ESXi 5.0, run the following command: #esxcli storage nmp device list
The value for Storage Array Type must be VMW_SATP_ALUA on each MD Series storage array.