16 Managing the SMI-S Provider
Changing the Debug Tracing Option
NOTE: After changing the tracing levels, stop and start OpenPegasus CIM server
for the changes to take effect. Turn on tracing only under the direction of your
technical support representative.
To change the debug tracing option:
1
Go to the directory where SMI-S Provider is installed. The default install
directories are:
•For Windows:
<%Program Files%>/Dell/pegasus/provider/array
For Linux:
/opt/dell/pegasus/array
2
Edit
providerTraceLog.properties
file in a text file editor.
Remove the pound sign (#) from the lines containing
File
,
Level
, and
Events
. You can edit the file name in the field
File
and directory you want.
This file contains the trace messages.
3
Save
providerTraceLog.properties
file and exit the text editor.
4
Stop and start the OpenPegasus CIM server. See "Starting and Stopping
the OpenPegasus CIM Server" on page 15.