Controlling access to hard drives
Communicating storage attributes and states to the storage system
NOTE: Do not return the storage controller battery with the failed storage controller. A new battery
is not included with a replacement storage controller.
Identify the Failed Storage Controller
To determine which storage controller failed, use the Dell Storage Client .
1. Click the Hardware tab.
2. In the Hardware tab navigation pane, select the Storage Center.
3. In the Hardware Alerts area, find the hardware alert that identifies the enclosure with the failed
storage controller.
Figure 23. Hardware Alert Identifying the Enclosure with the Failed
Storage Controller
4. In the Hardware tab navigation pane, expand the Enclosures entry.
5. Click I/O Modules. The status of each storage controller is displayed in the I/O Modules tab.
6. Select the failed storage controller to display its location in the IO Module View tab.
30