LED Indicators
• One single-color LED indicator for drawer 2 fault status
Drawer
• One single-color LED indicator for sideplane card and power status
• One single-color LED indicator for drawer fault status
• One single-color LED indicator for logical fault status
• One single-color LED indicator for cable fault status
• Six single-color LED indicators for data transfer status
Disk Drive In Carrier
(DDIC)
One single-color LED for drive fault status
6 Gb SAS IO module 14 one-color LED status indicators, four each for the three SAS ports and two
for the module status
Cooling module
• One single-color LED indicator for module status
• One single-color LED indicator for battery fault status (not currently used)
• One single-color LED indicator for fan fault status
Power Supply Unit (PSU)
• One single-color LED indicator for PSU fault status
• One single-color LED indicator for AC power fault status
• One single-color LED indicator for power status
Power Supplies
AC power supply (per power supply)
Wattage 2.8 kW
Voltage 200–240 VAC (16 A)
Heat dissipation 191-147 W
Input frequency 50/60 Hz
Max input power 1791 VA
Input current 7.4 A@241 VAC
Maximum inrush current Under typical line conditions and over the entire system ambient operating
range, the inrush current may reach 55 A per power supply for 10 ms or less
Available Hard Drive Power (per Slot)
Supported hard drive
power consumption
(continuous)
Up to 1.16 A at +5 V
Up to 1.6 A at +12 V
I/O Card Power (per Slot)
Maximum power
consumed by I/O Card
11 W at +12 V
Maximum available
power
100 W at +12 V
21