Figure 6. Storage System Connected to a Management Network
1. Management network switch 2. SCv2080 storage system
3. Storage controller 1 4. Storage controller 2
Back-End Cabling
An SCv2080 storage system may be installed with or without an expansion enclosure.
If you are installing an SCv2080 storage system with an expansion enclosure, you must connect the
expansion enclosure to the back-end SAS ports on the storage system.
If you are installing an SCv2080 storage system without an expansion enclosure, you must interconnect
back-end SAS ports on the storage system.
NOTE: A storage system with only one storage controller does not support back-end cabling.
Interconnecting Two Storage Controllers
When an SCv2080 with two storage controllers is deployed without expansion enclosures, the storage
controllers must be interconnected using SAS cables.
NOTE: The left storage controller is storage controller 1 and the right storage controller is storage
controller
2.
1. Connect a SAS cable between storage controller 1: port A and storage controller 2: port B.
2. Connect a SAS cable between storage controller 1: port B and storage controller 2: port A.
15