EasyManuals Logo

Dell Storage Center SCv2000 Getting Started Guide

Dell Storage Center SCv2000
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
Figure 7. Storage System Connected to a Management Network
1. Management network switch 2. SCv2000/SCv2020 storage system
3. Storage controller 1 4. Storage controller 2
Back-End Cabling
An SCv2000/SCv2020 storage system can be deployed with or without SC100/SC120 expansion
enclosures
.
If the storage system is installed without expansion enclosures, you must interconnect the two storage
controllers together.
Interconnecting Two Storage Controllers
When an SCv2000/SCv2020 with two storage controllers is deployed without expansion enclosures, the
storage controllers must be interconnected using SAS cables.
NOTE: The top storage controller is storage controller 1 and the bottom storage controller is
storage controller 2.
1. Connect a SAS cable between storage controller 1: port A and storage controller 2: port B.
2. Connect a SAS cable between storage controller 1: port B and storage controller 2: port A.
Figure 8. Interconnected Storage Controllers
1. SCv2000/SCv2020 storage system 2. Storage controller 1
3. Storage controller 2
Cabling an Expansion Enclosure to a Storage System
An SCv2000/SCv2020 storage system supports multiple SC100/SC120 expansion enclosures.
Use SAS cables to connect an SC100/SC120 expansion enclosure to an SCv2000/SCv2020 storage
system.
13

Other manuals for Dell Storage Center SCv2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell Storage Center SCv2000 and is the answer not in the manual?

Dell Storage Center SCv2000 Specifications

General IconGeneral
BrandDell
ModelStorage Center SCv2000
CategoryStorage
LanguageEnglish

Related product manuals