en
Notes: When carrying out these operations be careful
not to incline the appliance by more than 45°; in any case,
once the castors have been assembled, wait at least one hour
before turning it on.
Draining the condensate water
The condensate can be drained in 2 ways:
a) Draining into the tank
The condensate can be drained directly into the tank.
With this draining system, when the tank is full, the applian-
ce stops and the screen displays the tank alarm .
When the tank is full, remove it as shown in g. 2 and empty
it into a sink or a bathtub.
When the operation is complete, put the tank back in correct-
ly being careful to position the handle as shown in gure 3.
b) Continuous external draining
If you require the appliance to operate for a long period of
time without periodically emptying the tank, we advise you
to set up continuous draining as follows:
• Openthedooronthesideoftheapplianceandscrew
the pipe onto the tting, as shown in gure 4.
• Insertagardenhose(notsuppliedwiththeappliance)
intothepipeandleadtheendofthehosetoaoor-
level drain. Make sure the tank is inserted correctly.
• Makesurethehoseisneverplacedataheightabovethe
level of the pipe (g. 5).
Otherwise the water will continue to drain back into the
tank. Make sure there are no kinks in the hose.
Use